Tower Crane Foundation Design Calculation Example Official

For a 6 m square foundation, (L/6 = 1.0 , \textm). Since (e > L/6) (2.176 > 1.0), the resultant lies outside the middle third → partial uplift. Effective width (L' = 3 \times (L/2 - e) = 3 \times (3.0 - 2.176) = 2.472 , \textm). [ q_max = \frac2 \times N_totalB \times L' = \frac2 \times 19306.0 \times 2.472 = \frac386014.832 \approx 260.3 , \textkPa ]

Net bearing pressure at SLS = (q_max \approx 132.2 , \textkPa) Influence factor (I_s) for square footing ≈ 0.88 [ \delta = q_max \times B \times \frac1-\nu^2E_s \times I_s = 132.2 \times 7 \times \frac1-0.122530000 \times 0.88 ] [ \delta \approx 132.2\times7\times0.8775/30000\times0.88 = 0.0239 , \textm = 23.9 , \textmm ] Tower Crane Foundation Design Calculation Example

(M_Ed, per m = 4473 / 7 = 639 , \textkNm/m) [ A_s,req = \frac639\times10^60.87\times500\times0.9\times1409 = \frac639\times10^6551,000 \approx 1160 , \textmm^2/\textm ] For a 6 m square foundation, (L/6 = 1

Moment per meter width: [ M_Ed = q_max \times \fracc^22 \times \texteffective width factor ] Better to compute total moment = integral of pressure × distance. Given complexity, use standard formula from crane manuals: [ q_max = \frac2 \times N_totalB \times L'

For 7 m square, 2.5 m projection, (M_Ed \approx 0.5 \times q_max \times B \times c^2 = 0.5 \times 204.5 \times 7 \times 6.25 = 4473 , \textkNm) – that’s total moment.